You are here

Certificates

Search for certificates based on ID number, partner, supplier or standard reference, EN or designation

Supplier Product Namesort descending Compliance with the Standard Cert. ID | Rev.
UTC Fire & Security B.V. ATS3604E; ATS34xxE; ATS36xxE; ATS31xxE EN 50131-3:2009|Control and indicating equipment
EN 50136-2:2013|Requirements for Supervised Premises Transceiver (SPT)
EN 50131-10:2014|Application specific requirements for Supervised Premises Transceiver (SPT)
Environmental class: II
Security grade: 2 or 3 dependent on software setting
44|08
UTC Fire & Security B.V. ATS4601E; ATS46xxE EN 50131-3:2009|Control and indicating equipment
EN 50136-2:2013|Requirements for Supervised Premises Transceiver (SPT)
EN 50131-10:2014|Application specific requirements for Supervised Premises Transceiver (SPT)
Environmental class: II
Security grade: 2 or 3 dependent on software setting
45|08
BANDIT nv Bandit 240DB v3 EN 50131-8:2009|Security fog devices and systems
Environmental class: 2
Security grade: NA
172|01
CSL Dualcom Ltd CS5600 DualCom DigiAir and CS5601 DualCom DigiAir UDL EN 50131-10:2014|Application specific requirements for Supervised Premises Transceiver (SPT)
EN 50136-1:2012|General requirements for alarm transmission systems
EN 50136-2:2013|Requirements for Supervised Premises Transceiver (SPT)
Environmental class: II
Security grade: Security Grade 1-4 according to EN 50131-1:2006/A1:2009. Depend on the Security Grade of the housing in which the product is installed.
235|02
UTC Fire & Security B.V. DD1012AM; DD1012AM-D; DD1012; DD1012-D; DD1012PI; DD1012RAM EN 50131-2-4:2008|Combined passive infrared and microwave detectors
Environmental class: II
Security grade: 2 for DD1012, DD1012-D, DD1012PI, DD1012RAM; 3 for DD1012AM, DD1012AM-D
137|06
UTC Fire & Security B.V. DD666-D; DD666AM-D; DD669; DD669AM EN 50131-2-4:2008|Combined passive infrared and microwave detectors
Environmental class: II
Security grade: 2 for DD669, DD666-D; 3 for DD669AM, DD666AM-D
145|04
UTC Fire & Security B.V. DDV1016; DDV1016AM EN 50131-2-4:2008|Combined passive infrared and microwave detectors
Environmental class: II
Security grade: 2 for DDV1016; 3 for DDV1016AM
139|05
CSL Dualcom Ltd DualCom GradeShift UDL CS5301-01 EN 50131-10:2014|Application specific requirements for Supervised Premises Transceiver (SPT)
EN 50136-1:2012|General requirements for alarm transmission systems
EN 50136-2:2013|Requirements for Supervised Premises Transceiver (SPT)
Environmental class: II
Security grade: Security Grade 1-4 according to EN 50131-1:2006/A1:2009. Depend on the Security Grade of the housing in which the product is installed.
234|02
CSL Dualcom Ltd DualCom Pro EN 50131-10:2014|Application specific requirements for Supervised Premises Transceiver (SPT)
EN 50136-2:2013|Requirements for Supervised Premises Transceiver (SPT)
Environmental class: II
249|02
CSL Dualcom Ltd Emizon TCD EN 50136-3:2013|Requirements for Receiving Centre Transceiver (RCT)
Environmental class: II
Security grade: 2
243|01
CSL Dualcom Ltd Emizon TCD EN 50131-10:2014|Application specific requirements for Supervised Premises Transceiver (SPT)
EN 50136-2:2013|Requirements for Supervised Premises Transceiver (SPT)
Environmental class: II
244|02
CSL Dualcom Ltd Emizon TCD EN 54-21:2006|Fire alarm transmission systems and fault warning routing equipment 245|01
UTC Fire & Security B.V. EV1012; EV1012PI EN 50131-2-2:2008|Passive infrared detectors
Environmental class: II
Security grade: 2
80|04
UTC Fire & Security B.V. EV1012AM; EV1012AM-D EN 50131-2-2:2008|Passive infrared detectors
Environmental class: II
Security grade: 3
81|04
UTC Fire & Security B.V. EV1116; EV1116AM EN 50131-2-2:2008|Passive infrared detectors
Environmental class: II
Security grade: 2 for EV1116; 3 for EV1116AM
144|03
Digital Security Controls (DSC) a division of Tyco Safety Products Canada HS2128; HS2064; HS2032; HS2016; EN 50131-3:2009|Control and indicating equipment
EN 50131-6:2008|Power supply equipment
EN 50131-10:2014|Application specific requirements for Supervised Premises Transceiver (SPT)
Environmental class: II
Security grade: 2
Specifics: SPT structure : Type Z ATS category : Custom category C
201|06
Digital Security Controls (DSC) a division of Tyco Safety Products Canada HS2LCDP; HS2LCD; HS2ICNP; HS2ICN; HS2LCDPRO EN 50131-3:2009|Control and indicating equipment
Environmental class: II
Security grade: 2 (HS2ICNP; HS2ICN); 3 (HS2LCDP; HS2LCD; HS2LCDPRO)
209|03
Digital Security Controls (DSC) a division of Tyco Safety Products Canada HS2LCDRFP8; HS2LCDRF8; HS2ICNRFP8; HS2ICNRF8; HS2LCDRFPRO8 EN 50131-3:2009|Control and indicating equipment
EN 50131-5-3:2005 + A1:2008|Interconnections equipment using radio frequency techniques
Environmental class: II
Security grade: 2
208|03
Digital Security Controls (DSC) a division of Tyco Safety Products Canada HS2LCDWFPV8; HS2LCDWFP8; HS2LCDWF8; HS2LCDWFVPRO8; HS2LCDWFPRO8; WS9LCDWFP8; WS9LCDWF8 EN 50131-3:2009|Control and indicating equipment
EN 50131-5-3:2005 + A1:2008|Interconnections equipment using radio frequency techniques
EN 50131-6:2008|Power supply equipment
Environmental class: II
Security grade: 2
210|03
Digital Security Controls (DSC) a division of Tyco Safety Products Canada HS2LED EN 50131-3:2009|Control and indicating equipment
Environmental class: II
Security grade: 2
207|03

Pages