Fyreye MKII Modules Archives - Zeta Alarms https://www.zetaalarmsystems.com/products/fire-alarm-systems/mkii-addressable/mkii-interfaces/fyreye-mkii-modules/ Specialist manufacturers of high quality fire alarm systems for over three decades Wed, 24 Apr 2024 14:06:11 +0000 en-US hourly 1 https://wordpress.org/?v=6.9.4 https://www.zetaalarmsystems.com/wp-content/uploads/2024/05/cropped-Zeta-Logo-32x32.png Fyreye MKII Modules Archives - Zeta Alarms https://www.zetaalarmsystems.com/products/fire-alarm-systems/mkii-addressable/mkii-interfaces/fyreye-mkii-modules/ 32 32 Fyreye MKII Addressable Zone Monitor Module With Isolator https://www.zetaalarmsystems.com/product/fyreye-mkii-addressable-zone-monitor-module-with-isolator/ Wed, 24 Apr 2024 14:06:11 +0000 https://www.zetaalarmsystems.com/?post_type=product&p=1009 The ZAZM-MI is a conventional zone that can be used for conventional devices and/or for special detectors that are not available in addressable form such as UV detectors, Aspiration detectors etc.

The post Fyreye MKII Addressable Zone Monitor Module With Isolator appeared first on Zeta Alarms.

]]>
The ZAZM-MI is a conventional zone that can be used for conventional devices and/or for special detectors that are not available in addressable form such as UV detectors, Aspiration detectors etc.

The post Fyreye MKII Addressable Zone Monitor Module With Isolator appeared first on Zeta Alarms.

]]>
Fyreye MKII Addressable Sounder Control Module With Isolator https://www.zetaalarmsystems.com/product/fyreye-mkii-addressable-sounder-control-module-with-isolator/ Wed, 24 Apr 2024 14:04:56 +0000 https://www.zetaalarmsystems.com/?post_type=product&p=1007 The ZASC-MI can be used to supply a monitored 24Vdc to operate external relays and as a conventional sounder circuit to run bells or beacon flashers where the current consumption prohibits the use of addressable loop powered devices. The unit also includes input connections to monitor the external power supply status and report the findings […]

The post Fyreye MKII Addressable Sounder Control Module With Isolator appeared first on Zeta Alarms.

]]>
The ZASC-MI can be used to supply a monitored 24Vdc to operate external relays and as a conventional sounder circuit to run bells or beacon flashers where the current consumption prohibits the use of addressable loop powered devices. The unit also includes input connections to monitor the external power supply status and report the findings to the addressable control panel.

The post Fyreye MKII Addressable Sounder Control Module With Isolator appeared first on Zeta Alarms.

]]>
Fyreye MKII Addressable Input/Output Module with S/C Isolator (Loop Powered) https://www.zetaalarmsystems.com/product/fyreye-mkii-addressable-input-output-module-with-s-c-isolator-loop-powered/ Wed, 24 Apr 2024 14:04:00 +0000 https://www.zetaalarmsystems.com/?post_type=product&p=1005 The ZAIO-MI is both an input and output module in a modern enclosure (2 gang box size) with well protected electronic circuit board to minimise any damages during installation.

The post Fyreye MKII Addressable Input/Output Module with S/C Isolator (Loop Powered) appeared first on Zeta Alarms.

]]>
The ZAIO-MI is both an input and output module in a modern enclosure (2 gang box size) with well protected electronic circuit board to minimise any damages during installation.

The post Fyreye MKII Addressable Input/Output Module with S/C Isolator (Loop Powered) appeared first on Zeta Alarms.

]]>
Fyreye MKII Addressable Input Module with S/C Isolator (Loop Powered) https://www.zetaalarmsystems.com/product/fyreye-mkii-addressable-input-module-with-s-c-isolator-loop-powered/ Wed, 24 Apr 2024 14:03:00 +0000 https://www.zetaalarmsystems.com/?post_type=product&p=1004 The ZAI-MI is used to monitor and raise alarm from any ancillary equipment such as sprinkler flow switch, aspiration detectors, secondary fire control panel, beam detectors, external power supplies etc.

The post Fyreye MKII Addressable Input Module with S/C Isolator (Loop Powered) appeared first on Zeta Alarms.

]]>
The ZAI-MI is used to monitor and raise alarm from any ancillary equipment such as sprinkler flow switch, aspiration detectors, secondary fire control panel, beam detectors, external power supplies etc.

The post Fyreye MKII Addressable Input Module with S/C Isolator (Loop Powered) appeared first on Zeta Alarms.

]]>